Derating-Graph (Ambient Temperature)
RP60-S_DE
Series
125
100
75
Natural Convection
50
25
0
-25 0 25 35 50 60 70 80 90 100
Ambient Temperature Range (°C)
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at info@recom-development.at
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
Input Filter
Input Surge Voltage (100 ms max.)
12V Input
24V Input
48V Input
Input Reflected Ripple (nominal Vin and full load)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 7)
Remote OFF input current
DC-DC ON
DC-DC OFF
Nominal input
Output Power
Output Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
Minimum Load
RP60-xx3.305DE 3.3V Output
others
Line Regulation (LL-HL at full load)
Load Regulation (25% to 100% FL)
Cross Regulation (Note 8)
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
3.3V
Zener diode clamp (only single)
5V
12V
15V
Short Circuit Protection
Efficiency
9-18VDC
18-36VDC
36-75VDC
Pi Type
36VDC
50VDC
100VDC
40mAp-p
25ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
30mA
60W max.
±2%
±10%
800mA min.
10% of FL
±0.5%
±0.5%
±5%
1%/p-p of Vout max.
±0.02%/°C, max.
500µS
3.9V
6.2V
15V
18V
Hiccup, automatic recovery
see „Selection Guide“ table
continued on next page
www.recom-international.com
April-2005