NCP1219
However, if the fault lasts for more than 118 ms, then the
driver turns off and the device enters the VCC double hiccup
mode described earlier.
4.8 V
V FB
FB
VFB
3
+
VSS −
Soft−start
1 V max
118 ms
delay
Fault
disable Drv
The NCP1219 also has an internal temperature shutdown
circuit. If the junction temperature of the controller reaches
155°C (typical), the driver turns off and the controller
enters double hiccup mode.
Latched and Auto−Retry Options
The NCP1219A offers a latched fault circuitry. An
overload fault condition detected by the controller results
in a latch−off shutdown, requiring the controller to be reset
by cycling VCC (removing the ac line input). NCP1219B
provides an auto−retry circuit. All fault conditions except
the external latch fault result in the controller entering
double hiccup mode, attempting to restart the controller
every other VCC cycle, as mentioned earlier.
Figure 42. Block Diagram of Timer−Based Fault
Detection
Table 5. ORDERING INFORMATION
Device
Overcurrent
Frequency
Package
Shipping†
NCP1219AD65R2G
Latch
65 kHz
SOIC−7 (Pb−Free)
2500 / Tape & Reel
NCP1219BD65R2G
Auto−Recovery
65 kHz
SOIC−7 (Pb−Free)
2500 / Tape & Reel
NCP1219AD100R2G
Latch
100 kHz
SOIC−7 (Pb−Free)
2500 / Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
19