Embedded Power for
Business-Critical Continuity
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Rev.03.23.07
nxi100
2 of 4
OUTPUT SPECIFICATIONS
Voltage adjustability
See table
Output setpoint accuracy Vout
±0.8%
Ripple and noise
(See Note 1)
20 MHz bandwidth
15 mV pk-pk
Transient response
peak dev. settling time
(See Note 2)
50 mV
25 μs
Short circuit protection
Continuous current
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
12 Vin nominal
11-12.6 Vdc
Input current
Operating
No load
OUTEN low
13.6 A
300 mA
40 mA max.
UVLO turn ON voltage
UVLO turn OFF Voltage
9.9 V typ.
8.5 V typ.
Start-up time
Nominal line
10 ms
OUTEN
Logic compatibility
ON
OFF
Open circuit voltage
Ref. to -input
5 Vdc
0.8 Vdc max.
GENERAL CHARACTERISTICS
Efficiency
1.5 V output @ 60 A
87%
1.7 V output @ 60 A
87%
Switching frequency
Fixed (See Note 3)
990 kHz
Standards
94V-0 flammability rating
Weight
40 g (1.41 oz)
MTBF
Telcordia SR-332
850,000 hours
Mating connector
(See Note 4)
ENVIRONMENTAL SPECIFICATIONS
Maximum temperature Operating
shock
Temperature shock
Operating
Non-operating
Humidity
Operating
Storage
Altitude
Operating
Storage
Shock
Operational
Non-operational
Vibration
(See Note 5)
Electrostatic discharge
(See Note 6)
Thermal performance
(See Note 7)
Operational and
non-operational
Operating
Non-operating
Operating ambient
temperature
Non-operating
5 °C/10 min.
10 °C/hour
20 °C/hour
85% RH
95% RH
10,000 feet max.
50,000 feet max.
30 G 11 ms,
half sine wave
50 G 11 ms,
half sine wave
0.02 G2/Hz max.
ESD 15 kV
ESD 25 kV
0 °C to +60 °C