NT7502
Command
Code
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
Function
(1) Display ON/OFF
0
1
0
1
0
1
0
1
1
1
D
Turns on LCD panel when goes
high, and turns off when goes low
(2) Set Display Start Line 0 1 0 0 1
Display start address
Specifies RAM display line for
COM0
(3) Set Page Address
0101011
Page address
Sets the display RAM page in Page
Address register
(4-1) Set Column Address
0100001
4 higher bits
Higher column Sets 4 higher bits of column
address
address of display RAM in register
(4-2) Set column Address
4 lower bits
0100000
Lower column
address
Sets 4 lower bits of column address
of display RAM in register
(5) Read Status
0 0 1 Status
0 0 0 0 Reads the status information
(6) Write Display Data
1 1 0 Write data
Writes data in display RAM
(7) Read Display Data
1 0 1 Read data
Reads data from display RAM
(8) ADC select
0 1 0 1 0 1 0 0 0 0 D Sets the display RAM address
SEG output correspondence
(9) Normal/Reverse
Display
0
1
0
1
0
1
0
0
1
1
D
Normal indication when low, but full
indication when high
(10) Entire Display
ON/OFF
0
1
0
1
0
1
0
0
1
0
0 Selects normal display (0) or Entire
1 Display ON (1)
(11) Set LCD Bias
0 1 0 1 0 1 0 0 0 1 D Sets LCD drive voltage bias ratio
(12) Read-Modify-Write
0
1
0
1
1
1
0
0
0
0
0
Increments Column Address
counter during each write
(13) End
0 1 0 1 1 1 0 1 1 1 0 Releases the Read-Modify-Write
(14) Reset
0 1 0 1 1 1 0 0 0 1 0 Resets internal functions
(15) Common output
mode select
0
1
0
1
1
0
0D
*
*
*
Selects COM output scan direction.
* Invalid data
(16) Set Power Control
01000101
Operation Selects the power circuit operation
status
mode
(17) V0 voltage regulator
internal resistor ratio set
0
1
0
0
0
1
0
0
Resistor ratio
Select internal resistor ratio
(Rb / Ra) mode
(18) Electronic volume
mode set
Electronic Volume
Register set
01010000001
Sets the V0 output voltage
electronic volume register
010* *
Electronic control value
(19) Set static indicator
On/Off
010101011
Set Static indicator 0 1 0 * * * * * *
register
(20) Power Save
---------
(21) NOP
(22) Test Command
(23) Test Mode Reset
010111000
0101111* *
010111100
Note: Do not use any other command, or system malfunction may result.
0
D
Sets static indicator On/Off
0: OFF 1: ON
Mode Sets the flashing mode
-
-
Compound command of display
OFF and entire display ON
1 1 Command for non-operation
* * IC Test command. Do not use!
0 0 Command of test mode reset
31