1.2. When the built-in power is not being used immediately after turning on the power
Turn ON the VDD - VSS power keeping the RES pin = "L"
NT7502
When the power is stabilized
Release the reset state. (RES pin = "H")
Initialized state (Default)
Power saver START (multiple commands)
Function setup by command input (User setup)
(11) LCD bias setting
(8) ADC selection
(15) Common output state selection
Function setup by command input (User setup)
(17) Setting the built-in resistance radio
for regulation of the V0 voltage
(18) Electronic volume control
Power saver OFF
Function setup by command input (User setup)
(16) Power control setting
Arrange to start the power saver within 5ms after
releasing the reset statue.
Arrange to start power control setting within
5ms after turning OFF the power saver
This concludes the initialization
The target time of 5ms will vary depending on the panel characteristics and the capacitance of the smoothing capacitor.
Therefore, we suggest you to conduct an operation check using the actual equipment.
33