Only One Name Means ProTek’Tion™
application information
D+
D-
8
7
6
5
PLCDA03 - PLCDA24
GND
1
2
3
4
figure 1 - BIDIRECTIONAL COMMON-MODE USB PROTECTION
Circuit connectivity is as follows:
• Pins 1, 2, 3 and 4 connected to ground.
• Pins 5 and 6 connected to I/O Line D+.
• Pins 7 and 8 connected to I/O Line D-.
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
• The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
• The path length between the TVS device and the protected line should be minimized.
• All conductive loops including power and ground loops should be minimized.
• The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
• Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.
05076.R9 11/10
Page 6