A64E06161
Recommended DC Operating Conditions (TA = 0°C to + 70°C or -25°C to 85°C)
Symbol
VCC
VSS
VCCQ
VSSQ
VIH
VIL
CL
Parameter
Supply Voltage
Ground
Supply Voltage I/O only
Ground I/O only
Input High Voltage
Input Low Voltage
Output Load
Min.
Max.
Unit
1.7
1.95
V
0
0
V
1.7
VCC
V
0
0
V
1.4
VCCQ + 0.2
V
-0.2
+0.4
V
-
30
pF
Absolute Maximum Ratings*
*Comments
VCC to VSS . . . . . . . . . . . . . . . . . . -0.3V to VCC+0.3V
VCCQ to VSSQ . . . . . . . . . . . . . . . -0.3V to VCCQ+0.3V
IN, IN/OUT Volt to GND . . . . . . . . -0.3V to VCCQ + 0.3V
Storage Temperature, Tstg . . . . . . . . -55°C to +125°C
Power Dissipation, PT . . . . . . . . . . . . . . . . . . . . . 0.7W
Soldering Temp. & Time . . . . . . . . . . . . 260°C, 10 sec
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to this device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied or intended. Exposure to the absolute
maximum rating conditions for extended periods may affect
device reliability.
DC Electrical Characteristics (TA = 0°C to + 70°C or -25°C to 85°C, VCC = 1.7V to 1.95V, VCCQ = 1.7V to VCC GND = 0V)
Symbol
Parameter
⎜ILI⎥
Input Leakage Current
⎜ILO⎥ Output Leakage Current
ICC1
Dynamic Operating Current
-70
Min.
Max.
-
1
-
1
-
15
Unit
Conditions
μA
VIN = GND to VCCQ
CE = VIH or ZZ = VIL or
μA
OE = VIH or WE = VIL
VI/O = GND to VCCQ
Min. Cycle, Duty = 100%
mA
CE = VIL, ZZ = VIH
VIH = VCCQ, VIL = 0V,
II/O = 0mA
CE = VIL, ZZ = VIH
ICC2
-
3
mA
VIH = VCCQ, VIL = 0V,
f = 1MHz, II/O = 0mA
Standby Power
ISB1
Supply Current
VOL
Output Low Voltage
VOH
Output High Voltage
-
100
-
0.2
VCCQ-0.2
-
CE ≥ VCCQ - 0.2V
μA
ZZ ≥ VCCQ - 0.2V
VIN ≥ 0V
V
IOL = 0.2 mA
V
IOH = -0.2mA
(January, 2012, Version 1.2)
3
AMIC Technology, Corp.