MACH221 and MACH221SP (CONTINUED)
SWITCHING CHARACTERISTICS OVER OPERATING RANGES 1
Parameter
Symbol
Parameter Description
tAPW
Asynchronous Preset Width (Note 3)
tAPR
Asynchronous Preset Recovery Time (Note 3)
tEA
Input, I/O, or Feedback to Output Enable
tER
Input, I/O, or Feedback to Output Disable
tLP
tPD Increase for Powered-down Macrocell (Note 4)
tLPS
tS Increase for Powered-down Macrocell (Note 4)
tLPCO
tCO Increase for Powered-down Macrocell (Note 4)
tLPEA
tEA Increase for Powered-down Macrocell (Note 4)
-7
-10
-12
-14
-15
-18
Min Max Min Max Min Max Min Max Min Max Min Max Unit
5
10
12
14.5
15
18
ns
5
8
10
10
10
12
ns
9.5
12
12
14
15
18 ns
9.5
12
12
14
15
18 ns
10
10
10
10
10
10 ns
10
10
10
10
10
10 ns
0
0
0
0
0
0 ns
10
10
10
10
10
10 ns
Notes:
1. See “Switching Test Circuits” in the General Information section of the Vantis 1999 Data Book.
2. MACH221 tGO = 7 ns. MACH221SP tGO = 8 ns.
3. These parameters are not 100% tested, but are evaluated at initial characterization and at any time the design is modified where
this parameter may be affected.
4. If a signal is powered-down, this parameter must be added to its respective high-speed parameter.
30