DC-DC Converters Power Module type
Ordering information
DAS50
DA S 50 O 05
1
2
3
4
5
1Series name
R
2Single output
3Output wattage
4Input voltage
F :DC88 - 370V
48 :DC36 - 72V
5Output voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
DAS50F05
50
5V 10A
DAS50F12
50.4
12V 4.2A
DAS50F24
50.4
24V 2.1A
DAS504805
50
5V 10A
DAS504812
50.4
12V 4.2A
SPECIFICATIONS
MODEL
DAS50F05
DAS50F12
DAS50F24
DAS504805
DAS504812
VOLTAGE[V]
DC88 - 370
DC36 - 72
INPUT
CURRENT[A]
EFFICIENCY[%]
0.5typ (DCIN 130V, Io=100%) 0.25typ (DCIN 260V, Io=100%) 1.30typ (DCIN 48V, Io=100%) 1.28typ (DCIN 48V, Io=100%)
82typ
82typ
82typ
80typ
82typ
LEAKAGE CURRENT[mA] 0.3max (By UL, CSA, VDE and DEN-AN)
VOLTAGE[V]
5
12
24
5
12
CURRENT[A]
10
4.2
2.1
10
4.2
LINE REGULATION[mV] 20max
48max
96max
20max
48max
LOAD REGULATION[mV] 40max
100max
150max
40max
100max
RIPPLE[mVp-p] 0 to +85C*1 80max
-10 - 0C*1 140max
120max
160max
120max
160max
80max
140max
120max
160max
OUTPUT RIPPLE NOISE[mVp-p] 0 to +85C*1 150max
-10 - 0C*1 190max
200max
230max
200max
230max
150max
190max
200max
230max
TEMPERATURE REGULATION[mV] 0 to +85C 85max
-10 to +85C 95max
204max
228max
408max
456max
85max
95max
210max
230max
DRIFT[mV]
*2 20max
48max
96max
20max
48max
START-UP TIME[ms]
200max (DCIN 88V, Io=100%)
200max (DCIN 36V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed (TRM pin open)t10% adjustable by external VR
OUTPUT VOLTAGE SETTING[V] 4.85 - 5.35
11.4 - 12.6
22.8 - 25.2
4.85 - 5.35
11.4 - 12.6
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION Works at 115 - 140% of rating
CIRCUIT AND
OTHERS REMOTE SENSING
Provided
REMOTE ON/OFF
Between RC and -side of input:short - 1.2V ---output ON, 2.4 - 5.5V(or open)---output OFF, Compatible TTL
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA max, DC500V 50MW min (At Room Temperature)
DAS
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
-10 to +85C (Aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN Complies with UL60950-1, CSA C22.2 No.60950-1 and EN60950-1
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
58X12.7X115mm (WXHXD) / 120g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Measured by attaching the electrolytic capacitor of 220mF at output.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
* Parallel operation with other model is not possible.