Nexperia
74AHC1GU04-Q100
Inverter
6
VO
VO
(V)
mna399
50
ICC
(mA)
40
30
3
20
ID (drain current)
10
0
0
2
Fig 9. VCC = 5.5 V; IO = 0 A
0
4
VI (V)
6
Rbias = 560 kΩ
VCC
0.47 μF input
VI
(f = 1 kHz)
output 100 μF
A IO
GND
mna050
Fig 10. Test set-up for measuring forward
transconductance gfs = IO/VI at VO is
constant
40
gfs
(mA/V)
30
mna400
20
10
0
0
2
4
6
VCC (V)
Fig 11. Typical forward transconductance gfs as a function of the supply voltage at Tamb = 25 C
14. Application information
Some applications are:
• Linear amplifier (see Figure 12)
• In crystal oscillator design (see Figure 13)
Remark: All values given are typical unless otherwise specified.
74AHC1GU04_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 21 November 2012
© Nexperia B.V. 2017. All rights reserved
6 of 13