4.2. ZHP-r Definition :
Product Specification
CPF107J
ZHP-r is defined to be the impedance presented to the POTS connection by an ATU-R. The
equivalent circuit of ZHP-r is showing below. The ZHP-r is valid only for voice band
frequencies. The combination of capacitors in the ZHP-r is only representative.
4.3. DC characteristic :
All requirement of this specification can be met in the presence of all POTS loop currents
from 0mA to 130mA. This in line filter can pass POTS tip-to-ring dc voltages of 0V to 60V
and ringing signals of maximum 100Vrms at any frequency from15Hz to 30Hz with a dc
component in the range from 0V to 60V. The dc resistance from tip-to-ring at the line port
interface with the phone interface shorted, shall be less than or equal to 40 ohms for one
splitter.
The DC resistance from tip-to-ground and from ring-to-ground at the POTS interface with
the U-R interface open shall be greater than or equal to 10 Megohms. The ground point
shall be local building or green wire ground. As an objective , the dc resistance should
exceed 10MΩ.
4.4. Test loops :
This test loop model is valid only for voiceband frequencies.
140ohms
140ohms
140ohms
100nF
140ohms
Data sheet subject to change without notice
RDPS-POTS415(R1)09/19/2002
SHEET 5 OF 10