FS08...I
STANDARD SCR
Electrical Characteristics
SYMBOL
PARAMETER
CONDITIONS
IGT
IDRM / IRRM
VTM
VGT
VGD
IH
IL
dv / dt
Gate Trigger Current
Off-State Leakage Current
On-state Voltage
Gate Trigger Voltage
Gate Non Trigger Voltage
Holding Current
Latching Current
Critical Rate of Voltage Rise
VD = 12 VDC , RL = 33Ω. Tj = 25 ºC
VD = VDRM ,
Tj = 125 ºC
VR = VRRM ,
Tj = 25 ºC
at IT = 16 Amp, tp = 380 µs, Tj = 25 ºC
VD = 12 VDC , RL = 33Ω, Tj = 25 ºC
VD = VDRM , RL = 3.3KΩ,
Tj = 125 ºC
IT = 100 mA ,
Gate Open
IG = 1.2 IGT
RGK = 220Ω
VD = 0.67 x VDRM , Gate Open
MIN
MAX
MAX
MAX
MAX
MAX
MIN
MAX
MAX
MIN
di / dt
Rth(j-c)
Rth(j-a)
Critical Rate of Current Rise IG = 2 x IGT Tr ≤ 100 ns, Tj = 125 ºC MIN
Thermal Resistance
Junction-Case for DC
Tj = 125 ºC
Thermal Resistance
Junction-Amb
Tj = 125 ºC
Vt0
Threshold Voltage
Rd
Dynamic resistance
Tj = 125 ºC
Tj = 125 ºC
MAX
MAX
SENSITIVITY
Unit
08
09
0.5
2
mA
5
15
2
mA
5
µA
1.6
V
1.3
V
0.2
V
25
40
30
50
50
150
50
20
100
mA
mA
V/µs
A/µs
ºC/W
ºC/W
0.85
V
46
mΩ
PART NUMBER INFORMATION
FAGOR
F S 08
SCR
CURRENT
08 B
I 00 TU
PACKAGING
FORMING
CASE
VOLTAGE
SENSITIVITY
Dec - 02