Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Supply Voltages
Input Voltage
Symbol
TA
VDD1, VDD2
VIN+,VIN-
Min.
-40
4.5
-200
Max.
85
5.5
200
Unit
°C
V
mV
Note
1
DC Electrical Specifications
All specifications, typicals and figures are at the nominal operating conditions of VIN+ = 0 V, VIN- = 0 V,
TA = 25°C, VDD1 = 5 V and VDD2 = 5 V, unless otherwise noted.
Parameter
Symbol Min. Typ. Max. Unit
Test Conditions
Fig. Note
Input Offset Voltage
Gain
200 mV Nonlinearity
100 mV Nonlinearity
Maximum Input Voltage
Before Output Clipping
VOS -1.2 -0.2 1.0 mV
12
-3.0 -0.2 2.0
-40°C ≤ TA ≤ 85°C
1,2,3
4.5 ≤ (VDD1, VDD2) ≤ 5.5 V
G
7.60 8.00 8.40 V/V -200 ≤ VIN+ ≤ 200 mV
5
7.44 8.00 8.56
-200 ≤ VIN+ ≤ 200 mV
5,6,7
-40°C ≤ TA ≤ 85°C
4.5 ≤ (VDD1, VDD2) ≤ 5.5 V
NL200
0.1 0.2 % -200 ≤ VIN+ ≤ 200 mV
5, 8 3
0.4
-200 ≤ VIN+ ≤ 200 mV
5,8,9
-40°C ≤ TA ≤ 85°C
10,12
4.5 ≤ (VDD1, VDD2) ≤ 5.5 V
NL100
0.05 0.1
-100 ≤ VIN+ ≤ 100 mV
5, 8
0.2
-100 ≤ VIN+ ≤ 100 mV
5,8,9
-40°C ≤ TA ≤ 85°C
11,12
4.5 ≤ (VDD1, VDD2) ≤ 5.5 V
|VIN+|MAX
320
mV
4
Average Input Bias Current
IIN
-0.57
µA
Average Input Resistance
RIN
480
kΩ
Input DC Common-Mode
CMRRIN
69
dB
Rejection Ratio
13 4
5
Output Resistance
RO
1
Ω
Output Low Voltage
VOL
1.28
V VIN+ = 400 mV
46
Output High Voltage
VOH
3.84
V VIN+ = -400 mV
Output Common-Mode
Voltage
Input Supply Current
VOCM
IDD1
2.20 2.56 2.80 V -400 < VIN+ < 400 mV
-40°C ≤ TA ≤ 85°C
8.7 15.5 mA 4.5 ≤ (VDD1, VDD2) ≤ 5.5 V 14
Output Supply Current
IDD2
8.8 14.5 mA
15
Output Short-Circuit Current |IOSC|
11
mA VOUT = 0 V or VDD2
7
1-251