ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NMV05 types
Input voltage VIN, NMV12 types
Input voltage VIN, NMV15 types
OUTPUT CHARACTERISTICS
Parameter
Rated Power2
Voltage Set Point Accuracy
Line regulation
Conditions
TA=-40°C to 120°C
See tolerance envelope
High VIN to low VIN
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 minute
Resistance
Viso= 1000VDC
GENERAL CHARACTERISTICS
Parameter
Conditions
5V input types
Switching frequency
12V input types
15V input types
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Specification
All output types
Storage
5V output types
Case Temperature above ambient
All other output types
Cooling
Free air convection
TEMPERATURE DERATING GRAPH
1.5
1.0
85°C
0.5 Safe Operating Area
120°C
0
-40 0 50 100 150
Ambient Temperature (°C)
NMV 5V, 12V & 15V Series
3kVDC Isolated 1W Single & Dual Output DC/DC Converters
300°C
560mW
7V
15V
18V
Min.
Typ.
Max.
Units
1
W
1.0
1.2
%/%
Min.
Typ.
Max.
Units
3000
VDC
10
GΩ
Min.
Typ.
Max.
Units
120
135
150
170
kHz
90
110
Min.
Typ.
Max.
Units
-40
85
-50
125
°C
28
25
TOLERANCE ENVELOPE
+10%
+5%
V
NOM
Typical Load Line
+2.5%
-2.5%
-7.5%
10 25
50
75 100
Output Load Current (%)
The voltage tolerance envelope shows typical load regulation characteristics for this
product series. The tolerance envelope is the maximum output voltage variation due
to changes in output loading.
www.murata-ps.com/support
KDC_NMV.G03 Page 2 of 6