3.3V TAP AC Test Conditions
Input pulse levels ........ ........................................VSS to 3.3V
Input rise and fall times ..................... ..............................1 ns
Input timing reference levels ...........................................1.5V
Output reference levels...................................................1.5V
Test load termination supply voltage...............................1.5V
3.3V TAP AC Output Load Equivalent
1.5V
2.5V TAP AC Test Conditions
Input pulse levels......... ........................................VSS to 2.5V
Input rise and fall time .....................................................1 ns
Input timing reference levels................... ......................1.25V
Output reference levels .................. ..............................1.25V
Test load termination supply voltage .................... ........1.25V
2.5V TAP AC Output Load Equivalent
1.25V
TDO
ZO= 50Ω
50Ω
20pF
TDO
ZO= 50Ω
50Ω
20pF
TAP DC Electrical Characteristics And Operating Conditions
(0°C < TA < +70°C; VDD = 3.3V ±0.165V unless otherwise noted)[12]
Parameter
VOH1
Description
Output HIGH Voltage
VOH2
Output HIGH Voltage
VOL1
Output LOW Voltage
VOL2
Output LOW Voltage
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IX
Input Load Current
Note:
12. All voltages referenced to VSS (GND).
Conditions
IOH = –4.0 mA
IOH = –1.0 mA
IOH = –100 µA
IOL = 8.0 mA
IOL = 8.0 mA
IOL = 100 µA
GND < VIN < VDDQ
VDDQ = 3.3V
VDDQ = 2.5V
VDDQ = 3.3V
VDDQ = 2.5V
VDDQ = 3.3V
VDDQ = 2.5V
VDDQ = 3.3V
VDDQ = 2.5V
VDDQ = 3.3V
VDDQ = 2.5V
VDDQ = 3.3V
VDDQ = 2.5V
Min.
2.4
2.0
2.9
2.1
2.0
1.7
–0.5
–0.3
–5
Max.
Unit
V
V
V
V
0.4
V
0.4
V
0.2
V
0.2
V
VDD + 0.3
V
VDD + 0.3
V
0.7
V
0.7
V
5
µA