HT45F4M
Lithium Battery Backup Power ASSP MCU
Symbol
Parameter
Test Conditions
VDD
Conditions
Min. Typ. Max. Unit
System Reset Delay Time
(Power On Reset)
—
tRSTD
System Reset Delay Time
(Any Reset except Power On
—
Reset)
—
25
50
100 ms
—
8.3
16.7 33.3 ms
Note: 1. tSYS= 1/fSYS; tSUB = 1/fSUB
2. To maintain the accuracy of the internal HIRC oscillator frequency, a 0.1μF decoupling capacitor should
be connected between VDD and VSS and located as close to the device as possible.
ADC Electrical Characteristics
Symbol
Parameter
Test Conditions
VDD
Conditions
VADI
A/D Converter Input Voltage
—
—
VREF
A/D Converter Reference Voltage —
—
VBG
Reference Voltage
—
—
DNL
Differential Non-linearity
5V tADCK= 1.0μs
INL
Integral Non-linearity
5V tADCK= 1.0μs
IADC
Additional Power Consumption
if A/D Converter is used
3V No load (tADCK= 0.5μs )
5V No load (tADCK= 0.5μs )
IBG
Additional Power Consumption
if VBG Reference with Buffer is used
—
—
tADCK
A/D Converter Clock Period
—
—
tADC
A/D Conversion Time
(Include Sample and Hold Time)
— 12 bit ADC
tADS
A/D Converter Sampling Time
—
—
tON2ST A/D Converter On-to-Start Time
—
—
tBGS
VBG Turn on Stable Time
—
—
Ta= 25°C
Min. Typ. Max. Unit
0
—
VREF
V
2
—
VDD
V
-3% 1.25 +3% V
— ±1 ±2 LSB
— ±2 ±4 LSB
— 0.9 1.35 mA
— 1.2 1.8 mA
— 200 300 μA
0.5 — 10 μs
—
16
—
tADCK
—
4
2
—
200 —
—
tADCK
— μs
— μs
Rev. 1.10
12
January 15, 2013