MBM29F080A-55/-70/-90
To Top / Lineup / Index
• Write/Erase/Program Operations
Parameter Symbols
JEDEC Standard
Description
tAVAV
tAVWL
tWLAX
tDVWH
tWHDX
—
—
tGHWL
tGHEL
tELWL
tWLEL
tWHEH
tEHWH
tWLWH
tELEH
tWHWL
tEHEL
tWHWH1
tWC
Write Cycle Time
tAS
Address Setup Time
tAH
Address Hold Time
tDS
Data Setup Time
tDH
Data Hold Time
tOES Output Enable Setup Time
tOEH
Output Enable Read
Hold Time
Toggle Bit I and Data Polling
tGHWL Read Recover Time Before Write
tGHEL Read Recover Time Before Write
tCS
CE Setup Time
tWS
WE Setup Time
tCH
CE Hold Time
tWH
WE Hold Time
tWP
Write Pulse Width
tCP
Write Pulse Width
tWPH Write Pulse Width High
tCPH Write Pulse Width High
tWHWH1 Byte Programming Operation
tWHWH2
tWHWH2 Sector Erase Operation (Note 1)
—
tVCS
VCC Setup Time
—
tVIDR Rise Time to VID
—
tVLHT Voltage Transition Time (Note 2)
—
tWPP Write Pulse Width (Note 2)
—
tOESP OE Setup Time to WE Active (Note 2)
—
tCSP CE Setup Time to WE Active (Note 2)
—
tRB
Recover Time from RY/BY
26
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Typ.
Typ.
Max.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
MBM29F080A
Unit
-55
-70
-90
55
70
90 ns
0
0
0
ns
40
45
45 ns
25
30
45 ns
0
0
0
ns
0
0
0
ns
0
0
0
ns
10
10
10 ns
0
0
0
ns
0
0
0
ns
0
0
0
ns
0
0
0
ns
0
0
0
ns
0
0
0
ns
30
35
45 ns
30
35
45 ns
20
20
20 ns
20
20
20 ns
8
8
8
µs
1
1
1 sec
8
8
8 sec
50
50
50 µs
500 500 500 ns
4
4
4
µs
100
100
100 µs
4
4
4
µs
4
4
4
µs
0
0
0
ns