Definitions
Explanation of terms
Generally, all specifications are valid at the stated operat-
ing and measurement conditions and settings, with uninter-
rupted line voltage.
Specifications (guaranteed)
Describes warranted product performance that is valid under
the specified conditions.
Specifications include guard bands to account for the ex-
pected statistical performance distribution, measurement
uncertainties changes in performance due to environmental
changes and aging of components.
Typical values (characteristics)
Characteristics describe the product performance that is
usually met but not guaranteed. Typical values are based on
data from a representative set of instruments.
General characteristics
Give additional information for using the instrument. These
are general descriptive terms that do not imply a level of
performance.
Responsivity
For electro-optical devices (e.g. modulators ) this describes
the ratio of the optical modulated output signal amplitude
compared to the RF input amplitude of the device.
For opto-electrical devices (e.g. photodiodes) this describes
the ratio of at the RF amplitude at the device output to the
amplitude of the modulated optical signal input. .
Relative frequency response uncertainty
Describes the maximum deviation of the shape of a mea-
sured trace from the (unknown) real trace. This specification
has strong influence on the accuracy of the 3-dB cut-off fre-
quency determined for the device under test.
Absolute frequency response uncertainty
Describes the maximum difference between any amplitude
point of the measured trace and the (unknown) real value.
This specification is useful to determine the absolute re-
sponsivity of the device versus modulation frequency.
Frequency response repeatability
Describes the deviation of repeated measurement without
changing any parameter or connection relative to the aver-
age of this measurements.
Minimum measurable frequency response
Describes the average measured responsivity when no mod-
ulation signal is present at the device under test. This repre-
sents the noise floor of the measurement system.
Definition of LCA input and output names
LCA electrical port A
LCA electrical port B
LCA optical output LCA optical input
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]