DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

S25FL127S View Datasheet(PDF) - Spansion Inc.

Part Name
Description
Manufacturer
S25FL127S Datasheet PDF : 131 Pages
First Prev 121 122 123 124 125 126 127 128 129 130
Data Sheet (Preliminary)
Table 12.12 CFI Alternate Vendor-Specific Extended Query Parameter 84h Suspend Commands
Parameter Relative
Byte Address
Offset
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
Data
84h
08h
85h
2Dh
8Ah
64h
75h
2Dh
7Ah
64h
Description
Parameter ID (Suspend Commands
Parameter Length (The number of following bytes in this parameter. Adding this value to the
current location value +1 = the first byte of the next parameter)
Program suspend instruction code
Program suspend latency maximum (µs)
Program resume instruction code
Program resume to next suspend typical (µs)
Erase suspend instruction code
Erase suspend latency maximum (µs)
Erase resume instruction code
Erase resume to next suspend typical (µs)
Table 12.13 CFI Alternate Vendor-Specific Extended Query Parameter 88h Data Protection
Parameter Relative
Byte Address
Offset
00h
01h
02h
03h
04h
05h
Data
88h
04h
0Ah
01h
xxh
xxh
Description
Parameter ID (Data Protection)
Parameter Length (The number of following bytes in this parameter. Adding this value to the
current location value +1 = the first byte of the next parameter)
OTP size 2N bytes, FFh = not supported
OTP address map format, 01h = FL-S format, FFh = not supported
Block Protect Type, model dependent
00h = FL-P, FL-S, FFh = not supported
Advanced Sector Protection type, model dependent
01h = FL-S ASP.
Table 12.14 CFI Alternate Vendor-Specific Extended Query Parameter 8Ch Reset Timing
Parameter Relative
Byte Address
Offset
00h
01h
02h
03h
04h
05h
06h
07h
Data
Description
8Ch
06h
96h
01h
FFh (without
RESET# input)
23h (with RESET#
input)
00h
23h
00h
Parameter ID (Reset Timing)
Parameter Length (The number of following bytes in this parameter. Adding this value to the
current location value +1 = the first byte of the next parameter)
POR maximum value
POR maximum exponent 2N µs
Hardware Reset maximum value
Hardware Reset maximum exponent 2N µs
Software Reset maximum value, FFh = not supported
Software Reset maximum exponent 2N µs
April 25, 2013 S25FL127S_00_02
S25FL127S
121