Data Sheet (Preliminary)
Table 8.1 Command Set
Command
Name
Write Enable
write Disable
Read Status
Register
Write Status
Register
Read Data
Fast Read
Byte1 Code
06h
04h
05h
01h
03h
0Bh
Byte2
(S7-S0) (1)
S7-S0
A23-A16
A23-A16
Byte3
A15-A8
A15-A8
Byte4
A7-A0
A7-A0
Fast Read Dual
Output
3Bh
A23-A16
A15-A8
A7-A0
Page Program
Block Erase
(64 kB)
Sector Erase
(4 kB)
Chip Erase
Power-down
Release
Power-down /
Device ID
Manufacturer /
Device ID (3)
JEDEC ID
02h
D8h
20h
C7h/60h
B9h
ABh
90h
9Fh
A23-A16
A23-A16
A23-A16
A15-A8
A15-A8
A15-A8
A7-A0
A7-A0
A7-A0
dummy
dummy
dummy
dummy
dummy
(M7-M0)
(ID15-ID8)
manufacturer Memory Type
00h
(ID7-ID0)
Capacity
Byte5
Byte6
N-bytes
(Note 2)
(D7-D0)
dummy
dummy
(D7-D0)
(Next byte)
continuous
(D7-D0)
(Next byte)
continuous
I/O=
(D6,D4,D2,D0)
O=
(D7,D5,D3,D1)
(One byte per 4
clocks,
continuous)
(Next byte)
Up to 256
bytes
(ID7-ID0) (4)
(M7-M0)
(ID7-ID0)
Notes:
1. Data bytes are shifted with Most Significant Bit first. Byte fields with data in parenthesis “( )” indicate data being read from the device on
the SO pin.
2. The Status Register contents will repeat continuously until CS# terminates the instruction.
3. See Table 8.2, Manufacturer and Device Identification on page 15 for Device ID information.
4. The Device ID will repeat continuously until CS# terminates the instruction.
OP Code
ABh
90h
9Fh
Table 8.2 Manufacturer and Device Identification
(M7-M0)
(ID15-ID0)
01h
01h
4014h
(ID7-ID0)
13h
13h
8.1
Write Enable (06h)
The Write Enable command (Figure 8.1) sets the Write Enable Latch (WEL) bit in the Status Register to a 1,
which enables the device to accept a Write Status Register, program, or erase command.
The WEL bit must be set prior to every Page Program, Sector Erase, Block Erase, Chip Erase, and Write
Status Register command. The host system must first drive CS# low, write the WREN command, and then
drive CS# high.