Data Sheet
Read-ID (RDID)
The Read-ID instruction (RDID) identifies the devices as
SST25VF020B and manufacturer as SST. The device
information can be read from executing an 8-bit command,
90H or ABH, followed by address bits [A23-A0]. Following
the Read-ID instruction, the manufacturer’s ID is located in
address 00000H and the device ID is located in address
2 Mbit SPI Serial Flash
SST25VF020B
00001H. Once the device is in Read-ID mode, the manu-
facturer’s and device ID output data toggles between
address 00000H and 00001H until terminated by a low to
high transition on CE#.
Refer to Tables 7 and 8 for device identification data.
CE#
MODE 3 0 1 2 3 4 5 6 7 8
15 16
23 24 31 32 39 40 47 48 55 56
63
SCK MODE 0
SI
90 or AB
00
00
ADD1
MSB
MSB
HIGH
HIGH IMPEDANCE
SO
BF Device ID BF Device ID IMPEDANCE
MSB
Note: The manufacturer's and device ID output stream is continuous until terminated by a low to high transition on CE#.
Device ID = 8CH for SST25VF020B
1. 00H will output the manfacturer's ID first and 01H will output device ID first before toggling between the two.
1417 RdID.0
FIGURE 23: Read-ID Sequence
TABLE 8: Product Identification
Address
Manufacturer’s ID
Device ID
SST25VF020B
00000H
00001H
Data
BFH
8CH
T8.0 1417
©2010 Silicon Storage Technology, Inc.
22
S71417-02-000