VN610SP-E
Application information
3.4
Maximum demagnetization energy (VCC = 13.5 V)
Figure 20. Maximum turn-off current versus load inductance(1)
I LM AX (A)
1000
100
10
A
B
C
1
0 ,0 1
0 ,1
1
10
100
L( mH )
A = single pulse at TJstart = 150ºC
B= repetitive pulse at TJstart = 100ºC
C= repetitive pulse at TJstart = 125ºC
VIN, IL
Demagnetization
Demagnetization
Demagnetization
t
1. Values are generated with RL = 0Ω.
In case of repetitive pulses, Tjstart (at beginning of each demagnetization) of every pulse must not exceed
the temperature specified above for curves B and C.
Doc ID 10889 Rev 5