DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

STM32F031C4(2015) View Datasheet(PDF) - STMicroelectronics

Part Name
Description
Manufacturer
STM32F031C4 Datasheet PDF : 106 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
STM32F031x4 STM32F031x6
Functional overview
3.11
Timers and watchdogs
The STM32F031x4/x6 devices include up to five general-purpose timers and an advanced
control timer.
Table 5 compares the features of the different timers.
Table 5. Timer feature comparison
Timer
type
Timer
Counter
resolution
Counter
type
Prescaler
factor
DMA
request
generation
Capture/compare Complementary
channels
outputs
Advanced
control
TIM1
16-bit
Up, down, integer from
up/down 1 to 65536
Yes
4
3
TIM2
32-bit
Up, down, integer from
up/down 1 to 65536
Yes
4
-
TIM3
General
16-bit
Up, down, integer from
up/down 1 to 65536
Yes
4
-
purpose
TIM14
16-bit
Up
integer from
1 to 65536
No
1
-
TIM16
TIM17
16-bit
Up
integer from
1 to 65536
Yes
1
1
3.11.1
3.11.2
Advanced-control timer (TIM1)
The advanced-control timer (TIM1) can be seen as a three-phase PWM multiplexed on six
channels. It has complementary PWM outputs with programmable inserted dead times. It
can also be seen as a complete general-purpose timer. The four independent channels can
be used for:
• input capture
• output compare
• PWM generation (edge or center-aligned modes)
• one-pulse mode output
If configured as a standard 16-bit timer, it has the same features as the TIMx timer. If
configured as the 16-bit PWM generator, it has full modulation capability (0-100%).
The counter can be frozen in debug mode.
Many features are shared with those of the standard timers which have the same
architecture. The advanced control timer can therefore work together with the other timers
via the Timer Link feature for synchronization or event chaining.
General-purpose timers (TIM2, 3, 14, 16, 17)
There are five synchronizable general-purpose timers embedded in the STM32F031x4/x6
devices (see Table 5 for differences). Each general-purpose timer can be used to generate
PWM outputs, or as simple time base.
DocID025743 Rev 4
17/106
22

Share Link: 