Signal/Connection Descriptions
Ground
GROUND
Ground
Name
GNDP
GNDP1
GNDQ (4)
GNDA (4)
GNDD (4)
GNDC (2)
GNDH
GNDS (2)
Table 1-3 Grounds
Description
PLL Ground—GNDP is a ground dedicated for PLL use. The connection should be
provided with an extremely low-impedance path to ground. VCCP should be
bypassed to GNDP by a 0.47 µF capacitor located as close as possible to the chip
package. There is one GNDP connection.
PLL Ground 1—GNDP1 is a ground dedicated for PLL use. The connection should
be provided with an extremely low-impedance path to ground. There is one GNDP1
connection.
Quiet Ground—GNDQ is an isolated ground for the internal processing logic. This
connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors. There are four GNDQ
connections.
Address Bus Ground—GNDA is an isolated ground for sections of the address
bus I/O drivers. This connection must be tied externally to all other chip ground
connections. The user must provide adequate external decoupling capacitors.
There are four GNDA connections.
Data Bus Ground—GNDD is an isolated ground for sections of the data bus I/O
drivers. This connection must be tied externally to all other chip ground
connections. The user must provide adequate external decoupling capacitors.
There are four GNDD connections.
Bus Control Ground—GNDC is an isolated ground for the bus control I/O drivers.
This connection must be tied externally to all other chip ground connections. The
user must provide adequate external decoupling capacitors. There are two GNDC
connections.
Host Ground—GNDH is an isolated ground for the HDI08 I/O drivers. This
connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors. There is one GNDH
connection.
SHI, ESAI, DAX, and Timer Ground—GNDS is an isolated ground for the SHI,
ESAI, DAX, and Timer I/O drivers. This connection must be tied externally to all
other chip ground connections. The user must provide adequate external
decoupling capacitors. There are two GNDS connections.
1-4
DSP56362 Advance Information
MOTOROLA