DIGITAL SIGNAL PROCESSOR
KS9287
FWSEL, WSEL Frame Sync protection window size
0 0 +/- 3T
0 1 +/- 7T
1 0 +/- 13T
1 1 +/- 26T
ATTM, MUTE Control the Frame Sync attenuation
0 0 0 dB
0 1 - ∞ dB
1 0 -12 dB
1 1 -12 dB
3. CNTL-L, U ($BX, $CX)
When the number of tracks to be counted is input from MICOM, the CNTL-L, or CNTL-U register
loads the data into the tracking counter. This tracking counter is used for improving track jump
characteristics.
When the number of tracks to be jumped is input from MICOM, the track number is loaded from
MLTs positive edge to the register. If CNTL-L is selected, /COMPLETE signal is output to the
/ISTAT pin, and if CNTL-U is selected, /COUNT signal is output. The Timing Diagrams of the
tracking counters are Figure-2 and Figure-3.
MLT
CNTL-L,
CNTL-U
TRCNT
/ISTAT
=(/count)
/ISTAT
=(/complete)
N
N
N
N
N
N
Figure 2. Tracking Counter Timing Diagram
14