MC13109
Figure 15. Microprocessor Interface Data Latch Registers
MSB
14–Bit Tx Counter
LSB
Tx Counter Latch
MSB
14–Bit Rx Counter
LSB
Rx Counter Latch
U.K. Handset
Select
U.K. Base
Select
MSB
12–Bit Reference Counter
LSB
Reference Counter Latch
ALC
Disable
Not
Used
Limiter Clk
Disable Disable
2–Bit
Clk Out
Select
4–Bit
Volume
Control
Stdby
Rx
Tx
Rx
SP
Mode Mode Mute Mute Mute
15–Bit Mode Control Latch
5–Bit CD Threshold Control
Threshold Control Latch
Latch Address
1. (00000001)
2. (00000010)
3. (00000011)
4. (00000100)
5. (00000101)
6. (00000110)
4–Bit Test
Mode
3–Bit 1st LO
Capacitor Selection
7. (00000111)
7–Bit Auxillary Latch
Reference Frequency Selection
The “LO2 In” and “LO2 Out” pins form a reference oscillator
when connected to an external parallel–resonant crystal. The
reference oscillator is also the second local oscillator for the
RF Receiver. Figure 16 shows the relationship between
different crystal frequencies and reference frequencies for
cordless phone applications in various countries.
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Figure 16. Reference Frequency and
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Reference Divider Values
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Crystal
Frequency
Reference
Divider
Value
U.K. Base/
Handset
Divider
Reference
Frequency
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 10.24 MHz
2048
1
5.0 kHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 10.24 MHz
1024
4
2.5 kHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 11.15 MHz
2230
1
5.0 kHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 12.00 MHz
2400
1
5.0 kHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 11.15 MHz
1784
1
6.25 kHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 11.15 MHz
446
4
6.25 kHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ 11.15 MHz
446
25
1.0 kHz
Reference Counter
Figure 17 shows how the reference frequencies for the Rx
and Tx loops are generated. All countries except U.K. require
that the Tx and Rx reference frequencies be identical. In this
case, set “U.K. Base Select” and “U.K. Handset Select” bits
to “0”. Then the fixed divider is set to “1” and the Tx and Rx
reference frequencies will be equal to the crystal oscillator
frequency divided by the programmable reference counter
value. The U.K. is a special case which requires a different
reference frequency value fo Tx and Rx.
For U.K. base operation, set “U.K. Base Select” to “1”. For
U.K. handset operation, set “U.K. Handset Select” to “1”. The
Netherlands is also a special case since a 2.5 kHz reference
frequency is used for both the Tx and Rx reference and the
total divider value required is 4096 which is larger than the
maximum divide value available from the 12–bit reference
divider (4095). In this case, set “U.K. Base Select” to “1” and
set “U.K. Handset Select” to “1”. This will give a fixed divide
by 4 for both the Tx and Rx reference. Then set the reference
divider to 1024 to get a total divider of 4096.
Mode Control Register
Power saving modes, mutes, disables, volume control,
and microprocessor clock output frequency are all set by the
Control Register. Operation of the Control Register is
explained in Figures 18 through 25.
18