XC27x5X Derivatives
XC2000 Family / Base Line
Detailed Errata Description
device starts with a CAN bootstrap loader without limitation of the oscillator
settling time.
DPRAM_X.002 Undefined Data read from Dual-Port RAM (DPRAM)
Under special conditions, undefined data may be read from up to two word
locations L1, L2 in the DPRAM (address range F600H .. FDFFH).
The problem (affecting L1 and/or L2) is due to a redundancy circuit that may not
be properly disabled during the internal power-up reset sequence.
The problem may only occur when an operand that was written via port B is
(later) read via port A of the DPRAM. This is only the case when dual read
transfers are performed on both port A and B in parallel, which can only happen
in the two scenarios described below.
Note: Field experience has shown that the probability for this problem is
relatively low, as it further depends on several other conditions, e.g.:
- For an initial power-on reset without residual voltage, the problem is less
likely to occur at room temperature and above.
- The problem is more likely to occur when a residual voltage at VDDI1
was present at the last power-off/on cycle.
- If the problem does occur, then it is “latched” at power up. If it hasn’t
occurred in the current power cycle, then the problem only has the
possibility of occurring at the next power-off/on cycle.
- The addresses of L1 and L2 may vary from device to device and from one
power-off/on cycle to the next, but will not change for a given device until
the next power-off/on cycle; i.e. if L1 and L2 are not read via port A in one
of the critical scenarios described below, the problem has no effect on the
application.
Scenario 1 (Context Switch)
In this scenario, the problem may occur under the following sequence of
conditions (all conditions must be met):
1. L1 and/or L2 are located in the DPRAM in an area that is used to store the
context of a global register bank, and
Errata Sheet
23
V1.5, 2013-02