4282 Group
(6) Notes on handling
➀ A high-voltage is used for writing. Take care that overvoltage
is not applied. Take care especially at turning on the power.
➁ For the One Time PROM version, Renesas corp. does not
perform PROM writing test and screening in the assembly
process and following processes. In order to improve
reliability after writing, performing writing and test according
to the flow shown in Figure 34 before using is
recommended.
Writing with PROM programmer
Screening (Leave at 150 °C for 40 hours) (Note)
Verify test with PROM programmer
Function test in target device
Note: Since the screening temperature is higher
than storage temperature, never expose the
microcomputer to 150 °C exceeding 100
hours.
Fig. 34 Flow of writing and test of the product shipped in
blank
Rev.1.33 Mar 18, 2004 page 66 of 67