AC Test Timing Conditions:
Unless otherwise noted, all test conditions are as follows:
• TA = -40 to 85 oC
• Tj = -40 to 115 oC
• VDD_CORE = 1.42 to 1.58 V
VDD_IO = 3.0 to 3.6 V
• Input conditions:
All Inputs: tr, tf <= 1 ns
• Output Loading:
All Outputs: 50 pF
Electrical and Thermal Characteristics
3.3.1 AC Operating Frequency Data
Table 12 provides the operating frequency information for the MPC5200B.
Table 12. Clock Frequencies
1
e300 Processor Core
2
SDRAM Clock
3
XL Bus Clock
4
IP Bus Clock
5
PCI / Local Plus Bus Clock
6
PLL Input Range
Min
Max
—
400
—
133
—
133
—
133
—
66
15.6
35
Units
MHz
MHz
MHz
MHz
MHz
MHz
SpecID
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
3.3.2 Clock AC Specifications
SYSCLK
t CYCLE
t DUTY
t DUTY
VM
VM
VM
t RISE
CV IH
CV IL
Sym
t CYCLE
t RISE
Figure 2. Timing Diagram—SYS_XTAL_IN
Table 13. SYS_XTAL_IN Timing
Description
Min
SYS_XTAL_IN cycle time.(1)
28.6
SYS_XTAL_IN rise time.
—
t FALL
Max Units SpecID
64.1
ns
A2.1
5.0
ns
A2.2
MPC5200B Data Sheet, Rev. 1
Freescale Semiconductor
15