CXD2529Q
1-1. The meaning of the data for each address is explained below.
$4X commands
Command
AS3
AS2
AS1
AS0
CANCEL
0
0
0
0
FOCUS-ON
0
1
1
1
1 TRACK JUMP
1
0
0
RXF
10 TRACK JUMP
1
0
1
RXF
2N TRACK JUMP
1
1
0
RXF
N TRACK MOVE
1
1
1
RXF
RXF = 0 FORWARD
RXF = 1 REVERSE
• When the Focus-on command ($47) is canceled ($40), $02 is sent and the auto sequence is interrupted.
• When the Track jump/move commands ($48 to $4F) are canceled ($40), $25 is sent and the auto sequence
is interrupted.
$5X commands
Auto sequence timer setting
Setting timers: A, E, C, B
Command
D3
D2
D1
D0
Blind (A, E), Over flow (C) 0.18ms 0.09ms 0.05ms 0.02ms
Brake (B)
0.36ms 0.18ms 0.09ms 0.05ms
Ex.) D2 = D0 = 1, D3 = D1 = 0 (Initial Reset)
A = E = C = 0.11ms
B = 0.23ms
$6X commands
Auto sequence timer setting
Setting timer: D
Command
KICK (D)
D3
D2
11.6ms 5.8ms
Ex.) D3 = 0, D2 = D1 = D0 = 1(Initial Reset)
D = 10.15ms
D1
2.9ms
D0
1.45ms
$7X commands
Auto sequence track jump/move count setting (N)
Command
Auto sequence track
jump count setting
Data 1
Data 2
Data 3
Data 4
D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0
215 214 213 212 211 210 29 28 27 26 25 24 23 22 21 20
This command is used to set N when a 2N track jump and an N track move are executed for auto sequence.
• The maximum track count is 65,535, but note that with 2N track jumps the maximum track jump count is
determined by the mechanical limitations of the optical system.
• The number of track jump is counted according to the signals input from the CNIN pin.
– 15 –