Data Sheet
12. Absolute Maximum Ratings
Do not stress the device beyond the ratings listed in this section, or serious, permanent damage to the device
may result. These are stress ratings only and device operation at these or any other conditions beyond those
indicated in this section and in the Operating Ranges section of this document is not implied. Device
operation for extended periods at the limits listed in this section may affect device reliability.
Table 12.1 Absolute Maximum Ratings
Description
Ambient Storage Temperature
Voltage with Respect to Ground: All Inputs and I/Os
Rating
–65°C to +150°C
–0.5 V to VCC+0.5 V
Notes
1. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, input at I/O pins may overshoot VSS to –2.0 V for periods of
up to 20 ns. See Figure 12.2. Maximum DC voltage on output and I/O pins is 3.6 V. During voltage transitions output pins may overshoot
to VCC + 2.0 V for periods up to 20 ns. See Figure 12.2.
2. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than one second.
3. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only;
functional operation of the device at these or any other conditions above those indicated in the operational sections of this data sheet is not
implied. Exposure of the device to absolute maximum rating conditions for extended periods may affect device reliability.
Figure 12.1 Maximum Negative Overshoot Waveform
+0.8 V
–0.5 V
–2 V
20 ns
20 ns
20 ns
Figure 12.2 Maximum Positive Overshoot Waveform
20 ns
VCC +2.0 V
VCC+0.5 V
2.0 V
20 ns
20 ns
13. Operating Ranges
Table 13.1 Operating Ranges
Description
Ambient Operating Temperature (TA)
Positive Power Supply
Industrial
Voltage Range
Note
Operating ranges define those limits between which functionality of the device is guaranteed.
Rating
–40°C to +85°C
2.7 V to 3.6 V
January 7, 2008 S25FL016A_00_C3