HMP8154, HMP8156A
BIT
NUMBER
FUNCTION
7
BLANK
Timing Select
6
Reserved
5
BLANK Output
Control
4
BLANK
Polarity
3
HSYNC and
VSYNC Output
Control
2
HSYNC
Polarity
1
VSYNC
Polarity
0
FIELD
Polarity
TABLE 15. TIMING I/O REGISTER #1
SUB ADDRESS = 04H
DESCRIPTION
This bit is ignored unless BLANK is configured to be an output.
0 = Data for the first active pixel of the scan line must arrive the CLK cycle after the encoder
negates BLANK.
1 = Data for the first active pixel of the scan line must arrive immediately after the encoder
negates BLANK.
0 = BLANK is an input
1 = BLANK is an output
0 = Active low (low during blanking)
1 = Active high (high during blanking)
0 = HSYNC and VSYNC are inputs
1 = HSYNC and VSYNC are outputs
RESET
STATE
0B
0B
0B
0B
0B
0 = Active low (low during horizontal sync)
0B
1 = Active high (high during horizontal sync)
0 = Active low (low during vertical sync)
0B
1 = Active high (high during vertical sync)
0 = Active low (low during odd fields)
0B
1 = Active high (high during odd fields)
BIT
NUMBER
7-5
4
3
2-0
FUNCTION
Reserved
CLK Output Control
Aspect Ratio Mode
Reserved
TABLE 16. TIMING I/O REGISTER #2
SUB ADDRESS = 05H
DESCRIPTION
0 = CLK is an input
1 = CLK is an output
This bit must be set to “0” during BT.656 input mode.
0 = Rectangular (BT.601) pixels
1 = Square pixels
RESET
STATE
000B
0B
0B
00B
BIT
NUMBER
FUNCTION
7-6
Closed Captioning
Enable
5-0
Reserved
TABLE 17. AUXILIARY DATA ENABLE REGISTER
SUB ADDRESS = 06H
DESCRIPTION
00 = Closed caption disabled
01 = Closed caption enabled for odd fields: line 21 for NTSC, line 18 for (M) PAL, or line 22 for
(B, D, G, H, I, N, CN) PAL
10 = Closed caption enabled for even fields: line 284 for NTSC, line 281 for (M) PAL, or line
335 for (B, D, G, H, I, N, CN) PAL
11 = Closed caption enabled for both odd and even fields
RESET
STATE
00B
000000B
FN4343 Rev.5.00