S25FL127S
Table 59. CFI Alternate Vendor-Specific Extended Query Parameter 90h – Latency Code (Continued)
Parameter Relative
Byte Address
Offset
4Bh
4Ch
4Dh
4Eh
4Fh
50h
51h
52h
53h
54h
55h
56h
57h
Data
02h
FFh
FFh
00h
08h
FFh
FFh
FFh
FFh
FFh
FFh
FFh
FFh
Description
Latency Code for this row (10b)
Read mode cycles (FFh = command not supported at this frequency)
Read latency cycles
Read Fast mode cycles
Read Fast latency cycles
Read Dual Out mode cycles
Read Dual Out latency cycles
Read Quad Out mode cycles
Read Quad Out latency cycles
Dual I/O Read mode cycles
Dual I/O Read latency cycles
Quad I/O Read mode cycles
Quad I/O Read latency cycles
Table 60. CFI Alternate Vendor-Specific Extended Query Parameter F0h RFU
Parameter Relative
Byte Address
Offset
00h
01h
02h
...
10h
Data
F0h
0Fh
FFh
FFh
FFh
Description
Parameter ID (RFU)
Parameter Length (The number of following bytes in this parameter. Adding this value
to the current location value +1 = the first byte of the next parameter)
RFU
RFU
RFU
This parameter type (Parameter ID F0h) may appear multiple times and have a different length each time. The parameter is used to
reserve space in the ID-CFI map or to force space (pad) to align a following parameter to a required boundary.
Table 61. CFI Alternate Vendor-Specific Extended Query Parameter A5h, JEDEC SFDP Rev B
CFI Parameter
Relative Byte
Address Offset
00h
01h
02h
03h
04h
05h
SFDP Parameter
Relative Byte
Address Offset
00h
01h
02h
03h
SFDP Dword Name Data
Description
N/A
N/A
JEDEC Basic Flash
Parameter Dword-1
A5h CFI Parameter ID (A5h = JEDEC SFDP)
80h
CFI Parameter Length (The number of following bytes in this parameter. Adding this
value to the current location value +1 = the first byte of the next parameter)
Start of SFDP JEDEC parameter, located at 1120h in the overall SFDP address space.
Bits 7:5 = unused = 111b
E7h Bit 4:3 = 06h is status register write instruction & status register is default non-volatile=
00b
Bit 2 = Program Buffer > 64Bytes = 1 Bits 1:0 = Uniform 4KB erase unavailable = 11b
FFh Bits 15:8 = Uniform 4KB erase opcode = not supported = FFh
Bit 23 = Unused = 1b
Bit 22 = Supports Quad Out Read, Yes = 1b
F3h Bit 21 = Supports Quad I/O Read, Yes =1b
(FLxxxSA Bit 20 = Supports Dual I/O Read, Yes = 1b
G) Bit19 = Supports DDR, No = 0h
Bit 18:17 = Number of Address Bytes, 3 or 4 = 01b
Bit 16 = Supports Dual Out Read, Yes = 1b
FFh Bits 31:24 = Unused = FFh