S25FL128S, S25FL256S
Table 4.2 Power-Up / Power-Down Voltage and Timing
Symbol
VCC (min)
VCC (cut-off)
VCC (low)
tPU
tPD
Parameter
VCC (Minimum Operation Voltage)
VCC (Cut 0ff Where Re-initialization is Needed)
VCC (Low Voltage for Initialization to Occur)
VCC (Low Voltage for Initialization to Occur at Embedded)
VCC (min) to Read Operation
VCC (low) Time
Min
Max
Unit
2.7
V
2.4
V
1.0
2.3
V
300
µs
1.0
µs
VCC
VCC(max)
VCC(min)
Figure 4.3 Power-Up
tPU
Full Device Access
Time
VCC
VCC(max)
VCC(min)
VCC(cut-off)
Figure 4.4 Power-Down and Voltage Drop
No Device Access Allowed
tPU Device Access
Allowed
VCC(low)
tPD
Time